WebThe thickener design based on the solids flux data obtained in the Iaboratory involves the selection of the solids flux that will limit the operation of the thickener in other words, the … WebStelios Site for Technical Information Maintained by Rudi Steyn
Paste Thickener Design to Achieve Downstream Requirements
WebFeb 2, 2011 · Clarifier design, usually based on "long tube" data, is based on the overflow velocity and the detention time, and calculations are quite simple. Thickener design involves the application of one of a number of alternative models together with jar test data, and is based either on the combined Kynch (1952) and Coe and Clevenger (1916) analysis ... WebWater Circuits Design and Tailings Management. Dilip Kumar, Deepak Kumar, in Sustainable Management of Coal Preparation, 2024. 14.5.1.1 High-Rate Thickener (HRT) High … bismuth reddit
How to Size a Thickener - Mineral Processing & Metallurgy
WebThere is a long history of innovations in thickener design to enable the production of higher densities. Large High Density thickeners were pioneered in the late 1980s. The roots of Deep Cone thickeners go back to the 1960s. Over the last two decades significant advances in the design of thickeners has enabled production of In high rate thickener (HRT) designs the rise rate or solids loading will dictate the required tank diameter for any given throughput. In high compression (HCT) and paste (PT) applications the bed depth or the mass of solids in the thickener must also be selected to ensure the desired underflow density from the … See more The measurable parameters that can be used for thickener control include thickener feed flow rate, feed density, underflow density, overflow clarity, bed level, bed mass, rake … See more Rake torque is the most fundamental instrument and an accurate indicator of when things have already gone really wrong! Under normal … See more Bed mass is utilized to control thickener inventory. Bed mass is generally measured by a pressure transducers mounted at the bottom of the tank (figure 4). These pressure transducers’ are best located in the cone or close to … See more Bed level is a frequently installed instrument and can be installed and serviced during normal thickener operation. Instruments measure the height of the interface … See more Webdesign calculations to determine the required thickener area, the most important design parameter, and ultimately the maximum steady state underflow concentration that is … dar middletown ohio